Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 97
Filtrar
1.
Transl Pediatr ; 13(2): 248-259, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38455742

RESUMO

Background: The neutrophil-lymphocyte ratio (NLR) is an easily accessible and inexpensive biomarker that has been shown to predict morbidity and mortality in congenital cardiac surgery. However, its regulatory mechanism remains unclear. This study aims to compare and correlate the tumor necrosis factor alpha (TNF-α), interleukin (IL)-1ß, IL-6, and IL-10 messenger RNAs (mRNAs) with the NLR in patients with tetralogy of Fallot (ToF) and ventricular septal defect (VSD). Methods: A prospective translational study was conducted on 10 children with ToF and 10 with VSD, aged between 1 and 24 months. The NLR was calculated from the blood count taken 24 hours before surgery. The expression of these mRNAs was analyzed in the myocardial tissue of the right atrium prior to cardiopulmonary bypass. Results: Patients with ToF exhibited a higher NLR [ToF 0.46 (interquartile range; IQR) 0.90; VSD 0.28 (IQR 0.17); P=0.02], longer mechanical ventilation time [ToF 24 h (IQR 93); VSD 5.5 h (IQR 8); P<0.001], increased use of vasoactive drugs [ToF 2 days (IQR 1.75); VSD 0 (IQR 1); P=0.01], and longer ICU [ToF 5.5 (IQR 1); VSD 2 (IQR 0.75); P=0.02] and hospital length of stays [ToF 18 days (IQR 17.5); VSD 8.5 days (IQR 2.5); P<0.001]. A negative correlation was found between NLR and oxygen saturation (SaO2) (r=-0.44; P=0.002). In terms of mRNA expression, the ToF group showed a lower expression of IL-10 mRNA (P=0.03). A positive correlation was observed between IL-10-mRNA and SaO2 (r=0.40; P=0.07), and a negative correlation with NLR (r=-0.27; P=0.14). Conclusions: Patients with ToF demonstrated a higher preoperative NLR and lower IL-10 mRNA expression by what appears to be a pro-inflammatory phenotype of cyanotic patients.

2.
Heliyon ; 10(4): e25406, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38370176

RESUMO

Objective: This study aims to develop a predictive model using artificial intelligence to estimate the ICU length of stay (LOS) for Congenital Heart Defects (CHD) patients after surgery, improving care planning and resource management. Design: We analyze clinical data from 2240 CHD surgery patients to create and validate the predictive model. Twenty AI models are developed and evaluated for accuracy and reliability. Setting: The study is conducted in a Brazilian hospital's Cardiovascular Surgery Department, focusing on transplants and cardiopulmonary surgeries. Participants: Retrospective analysis is conducted on data from 2240 consecutive CHD patients undergoing surgery. Interventions: Ninety-three pre and intraoperative variables are used as ICU LOS predictors. Measurements and main results: Utilizing regression and clustering methodologies for ICU LOS (ICU Length of Stay) estimation, the Light Gradient Boosting Machine, using regression, achieved a Mean Squared Error (MSE) of 15.4, 11.8, and 15.2 days for training, testing, and unseen data. Key predictors included metrics such as "Mechanical Ventilation Duration", "Weight on Surgery Date", and "Vasoactive-Inotropic Score". Meanwhile, the clustering model, Cat Boost Classifier, attained an accuracy of 0.6917 and AUC of 0.8559 with similar key predictors. Conclusions: Patients with higher ventilation times, vasoactive-inotropic scores, anoxia time, cardiopulmonary bypass time, and lower weight, height, BMI, age, hematocrit, and presurgical oxygen saturation have longer ICU stays, aligning with existing literature.

3.
Rev. bras. cir. cardiovasc ; 39(1): e20230110, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1521674

RESUMO

ABSTRACT Objective: To define a reference chart comparing pressure drop vs. flow generated by a set of arterial cannulae currently utilized in cardiopulmonary bypass conditions in pediatric surgery. Methods: Cannulae from two manufacturers were selected considering their design and outer and inner diameters. Cannula performance was evaluated in terms of pressure drop vs. flow during simulated cardiopulmonary bypass conditions. The experimental circuits consisted of a Jostra HL-20 roller pump, a Quadrox-i pediatric oxygenator (Maquet Cardiopulmonary AG, Rastatt, Germany), and a custom pediatric tubing set. The circuit was primed with lactated Ringer's solution only (first condition) and with human packed red blood cells added (second condition) to achieve a hematocrit of 30%. Cannula sizes 8 to 16 Fr were inserted into the cardiopulmonary bypass circuit with a "Y" connector. The flow was adjusted in 100 ml/min increments within typical flow ranges for each cannula. Pre-cannula and post-cannula pressures were measured to calculate the pressure drop. Results: Utilizing a pressure drop limit of 100 mmHg, our results suggest a recommended flow limit of 500, 900, 1400, 2600, and 3100 mL/min for Braile arterial cannulae sizes 8, 10, 12, 14, and 16 Fr, respectively. For Medtronic DLP arterial cannulae sizes 8, 10, 12, 14, and 16 Fr, the recommended flow limit is 600, 1100, 1700, 2700, and 3300 mL/min, respectively. Conclusion: This study reinforces discrepancies in pressure drop between cannulae of the same diameter supplied by different manufacturers and the importance of independent translational research to evaluate components' performance.

4.
Braz J Cardiovasc Surg ; 39(1): e20230110, 2023 11 09.
Artigo em Inglês | MEDLINE | ID: mdl-37947184

RESUMO

OBJECTIVE: To define a reference chart comparing pressure drop vs. flow generated by a set of arterial cannulae currently utilized in cardiopulmonary bypass conditions in pediatric surgery. METHODS: Cannulae from two manufacturers were selected considering their design and outer and inner diameters. Cannula performance was evaluated in terms of pressure drop vs. flow during simulated cardiopulmonary bypass conditions. The experimental circuits consisted of a Jostra HL-20 roller pump, a Quadrox-i pediatric oxygenator (Maquet Cardiopulmonary AG, Rastatt, Germany), and a custom pediatric tubing set. The circuit was primed with lactated Ringer's solution only (first condition) and with human packed red blood cells added (second condition) to achieve a hematocrit of 30%. Cannula sizes 8 to 16 Fr were inserted into the cardiopulmonary bypass circuit with a "Y" connector. The flow was adjusted in 100 ml/min increments within typical flow ranges for each cannula. Pre-cannula and post-cannula pressures were measured to calculate the pressure drop. RESULTS: Utilizing a pressure drop limit of 100 mmHg, our results suggest a recommended flow limit of 500, 900, 1400, 2600, and 3100 mL/min for Braile arterial cannulae sizes 8, 10, 12, 14, and 16 Fr, respectively. For Medtronic DLP arterial cannulae sizes 8, 10, 12, 14, and 16 Fr, the recommended flow limit is 600, 1100, 1700, 2700, and 3300 mL/min, respectively. CONCLUSION: This study reinforces discrepancies in pressure drop between cannulae of the same diameter supplied by different manufacturers and the importance of independent translational research to evaluate components' performance.


Assuntos
Cânula , Ponte Cardiopulmonar , Criança , Humanos , Hemodinâmica , Modelos Cardiovasculares , Desenho de Equipamento
5.
Transplant Proc ; 55(6): 1449-1450, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37516626

RESUMO

Patients who have undergone organ transplantation are immunosuppressed hosts, leaving them at a higher risk of infections. SARS-COV-2 has been shown to affect heart-transplanted patients. In this case report, we present the case of a 14-year-old heart transplant recipient who developed signs and symptoms of heart failure, along with fatigue, after a COVID-19 infection. An endomyocardial biopsy was performed to diagnose rejection and to evaluate whether this was myocarditis due to SARS-COV-2. The biopsy showed intense acute cellular rejection (3R) and antibody rejection PAMR1 H+ but was negative for the SARS-CoV-2 virus. The patient received organ rejection therapy with high-dose methylprednisolone and human immunoglobulin. After treatment, her heart function recovered, with biopsy investigations showing a lower level of cellular rejection (1R).


Assuntos
COVID-19 , Transplante de Coração , Miocardite , Humanos , Adolescente , Feminino , Miocardite/diagnóstico , Miocardite/patologia , Rejeição de Enxerto , SARS-CoV-2 , Transplante de Coração/efeitos adversos , Biópsia , Teste para COVID-19
6.
Transplant Proc ; 55(6): 1429-1430, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37344300

RESUMO

Heart transplantation is the treatment of choice for children and adults with congenital heart disease. We report the heart transplant single-center experience. The number of transplantations has increased over the last 3 decades. The Kaplan-Meier survival curves in the first, second, and third decades at 5 and 10 years were 69% and 59%, 62% and 52%, and 66% and 60%, respectively.


Assuntos
Cardiopatias Congênitas , Transplante de Coração , Adulto , Humanos , Criança , Resultado do Tratamento , Transplante de Coração/efeitos adversos , Cardiopatias Congênitas/cirurgia , Estimativa de Kaplan-Meier , Estudos Retrospectivos
7.
Transplant Proc ; 55(6): 1425-1428, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37120344

RESUMO

BACKGROUND: In countries where organ donation is scarce, mortality in the pediatric heart transplant waiting list is high, and ventricular assist devices (VADs) are therapeutic alternatives in these situations. Berlin Heart EXCOR is currently 1 of the few VADs specific for children. METHODS: This retrospective study includes pediatric patients who underwent Berlin Heart EXCOR placement in a Brazilian hospital between 2012 and 2021. Clinical and laboratory data at the time of VAD implantation and the occurrence of complications and outcomes (success as a bridge to transplant or death) were analyzed. RESULTS: Eight patients, from 8 months to 15 years, were included: 6 with cardiomyopathy and 2 with congenital heart disease. Six were on Intermacs 1 and 2 on Intermacs 2. The most common complications observed were stroke and right ventricular dysfunction. Six were transplanted, and 2 died. Those submitted to transplant had a higher mean weight than those who died, with no statistically significant difference. The underlying disease had no impact on the outcome. The group undergoing transplant had lower brain natriuretic peptide and lactate values, but no laboratory variable showed a statistically significant difference in the outcome. CONCLUSION: A VAD is an invasive treatment with potentially serious adverse effects and is still poorly available in Brazil. However, as a bridge to transplant, it is a useful treatment for children in progressive clinical decline. In this study, we did not observe any clinical or laboratory factor at the time of VAD implantation that implied better outcomes.


Assuntos
Sistema Cardiovascular , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Criança , Humanos , Insuficiência Cardíaca/cirurgia , Estudos Retrospectivos , Resultado do Tratamento , Transplante de Coração/efeitos adversos , Coração Auxiliar/efeitos adversos
8.
Front Pediatr ; 10: 860394, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36518783

RESUMO

We will report a case of a desmoid tumour (DT), which developed at the surgical site of the pacemaker after a late childhood heart transplant. Patients with idiopathic dilated cardiomyopathy followed up in the paediatric cardiology service. It evolved with the dissociation of ventricular rhythm caused by severe heart failure, which led to the implantation of a cardiac resynchronization device prior to heart transplantation. The progression to end-stage heart disease culminated in a heart transplant at 12 years old. One year after the transplant, at the age of 13 years, he presented a progressively growing mass on the generator site of the resynchronization device. The initial decision was to remove the device. During the removal surgery, there was no haematoma or fluid collection. However, there was a progression of the lesion. The lesion was biopsied with the anatomopathological diagnosis of a DT. Resection surgery happened 4 months after the start of the mass growth. At that time, the tumour reached 20 cm in diameter. The lesion infiltrated the pectoralis major muscle and this muscle was resected partially en bloc with the lesion. The defect had primary closure. The patient evolved without postoperative complications and was discharged on the 14th postoperative day. The surgical specimen came with negative circumferential margins. However, the deep margin was microscopically positive. Due to deep involvement, the patient underwent adjuvant radiotherapy. Currently, the patient is under clinical follow-up and has no evidence of tumour recurrence. DT is a rare tumour, with unpredictable courses. Surgery can be considered in the progression of lesions. Treatment is justified by long survival after a heart transplant and in DT patients. DT is a differential diagnosis to be considered in progressive growth lesions.

9.
Rev. bras. cir. cardiovasc ; 37(6): 952-954, Nov.-Dec. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1407318

RESUMO

Abstract Kawasaki disease (KD) is an inflammatory condition that may affect genetically predisposed individuals in pediatric ages after infectious/environmental triggering. An infrequent finding associated with KD is ascending aortic aneurysm during or after the acute phase of the disease. In this Multimedia presentation, we describe a three-year-old girl submitted to surgical treatment.

13.
Braz J Cardiovasc Surg ; 37(6): 952-954, 2022 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34673520

RESUMO

Kawasaki disease (KD) is an inflammatory condition that may affect genetically predisposed individuals in pediatric ages after infectious/environmental triggering. An infrequent finding associated with KD is ascending aortic aneurysm during or after the acute phase of the disease. In this Multimedia presentation, we describe a three-year-old girl submitted to surgical treatment.


Assuntos
Aneurisma Aórtico , Aneurisma Coronário , Síndrome de Linfonodos Mucocutâneos , Feminino , Humanos , Criança , Pré-Escolar , Síndrome de Linfonodos Mucocutâneos/complicações , Síndrome de Linfonodos Mucocutâneos/cirurgia , Dilatação , Aneurisma Coronário/diagnóstico por imagem , Aneurisma Coronário/etiologia , Aneurisma Coronário/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/etiologia , Aneurisma Aórtico/cirurgia
14.
Front Immunol ; 12: 774780, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34899730

RESUMO

Background and Aims: Congenital heart diseases (CHDs) are diagnosed in approximately 9 in 1,000 newborns, and early cardiac corrective surgery often requires partial or complete thymectomy. As the long-term effect of early thymectomy on the subsequent development of the immune system in humans has not been completely elucidated, the present study aimed to evaluate the effects of thymus removal on the functional capacity of the immune system after different periods. Methods: A systematic review of the literature was performed using MEDLINE, EMBASE, LILACS and Scopus. The inclusion criteria were original studies that analyzed any component of the immune system in patients with CHD who had undergone thymectomy during cardiac surgery in the first years of life. The results were evaluated for the quality of evidence. Results: Twenty-three studies were selected and showed that patients who underwent a thymectomy in the first years of life tended to exhibit important alterations in the T cell compartment, such as fewer total T cells, CD4+, CD8+, naïve and CD31+ T cells, lower TRECs, decreased diversity of the TCR repertoire and higher peripheral proliferation (increased Ki-67 expression) than controls. However, the numbers of memory T cells and Treg cells differed across the selected studies. Conclusions: Early thymectomy, either partial or complete, may be associated with a reduction in many T cell subpopulations and TCR diversity, and these alterations may persist during long-term follow-up. Alternative solutions should be studied, either in the operative technique with partial preservation of the thymus or through the autograft of fragments of the gland. Systematic Review Registration: Prospero [157188].


Assuntos
Desenvolvimento Infantil , Sistema Imunitário/imunologia , Subpopulações de Linfócitos T/imunologia , Timectomia/efeitos adversos , Timo/cirurgia , Fatores Etários , Variação Antigênica , Proliferação de Células , Criança , Pré-Escolar , Humanos , Sistema Imunitário/crescimento & desenvolvimento , Memória Imunológica , Lactente , Recém-Nascido , Fenótipo , Receptores de Antígenos de Linfócitos T/imunologia , Timo/imunologia , Resultado do Tratamento
15.
Braz J Cardiovasc Surg ; 36(5): 589-598, 2021 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-34787990

RESUMO

INTRODUCTION: The Technical Performance Score (TPS) was developed and subsequently refined at the Boston Children's Hospital. Our objective was to translate and validate its application in a developing country. METHODS: The score was translated into the Portuguese language and approved by the TPS authors. Subsequently, we studied 1,030 surgeries from June 2018 to October 2020. TPS could not be assigned in 58 surgeries, and these were excluded. Surgical risk score was evaluated using Risk Adjustment in Congenital Heart Surgery (or RACHS-1). The impact of TPS on outcomes was studied using multivariable linear and logistic regression adjusting for important perioperative covariates. RESULTS: Median age and weight were 2.2 (interquartile range [IQR] = 0.5-13) years and 10.8 (IQR = 5.6-40) kilograms, respectively. In-hospital mortality was 6.58% (n=64), and postoperative complications occurred in 19.7% (n=192) of the cases. TPS was categorized as 1 in 359 cases (37%), 2 in 464 (47.7%), and 3 in 149 (15.3%). Multivariable analysis identified TPS class 3 as a predictor of longer hospital stay (coefficient: 6.6; standard error: 2.2; P=0.003), higher number of complications (odds ratio [OR]: 1.84; 95% confidence interval [CI]: 1.1-3; P=0.01), and higher mortality (OR: 3.2; 95% CI: 1.4-7; P=0.004). CONCLUSION: TPS translated into the Portuguese language was validated and showed to be able to predict higher mortality, complication rate, and prolonged postoperative hospital stay in a high-volume Latin-American congenital heart surgery program. TPS is generalizable and can be used as an outcome assessment tool in resource diverse settings.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Adolescente , Boston , Criança , Pré-Escolar , Países em Desenvolvimento , Mortalidade Hospitalar , Humanos , Lactente , Tempo de Internação , Complicações Pós-Operatórias , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
16.
Rev. bras. cir. cardiovasc ; 36(5): 607-613, Sept.-Oct. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1351640

RESUMO

Abstract Introduction: Elevated neutrophil-lymphocyte ratio (NLR) has been associated with poorer outcomes in cyanotic patients undergoing single ventricle palliation. Little is known about this biomarker on patients with tetralogy of Fallot (TOF), the most common cyanotic congenital heart disease. Our objective is to study the impact of preoperative NLR on outcomes of TOF patients undergoing total repair. Methods: This retrospective study included 116 consecutive patients between January 2014 and December 2018. Preoperative NLR was measured from the last complete blood count test before the surgery. Using the cutoff value of 0.80, according to the receiver-operating characteristic (ROC) curve, the sample was divided into two groups (NLR < 0.80 and ≥ 0.80). The primary endpoint was hospital length of stay (LOS). Results: ROC curves showed that higher preoperative NLR was associated with longer hospital LOS, with an area under the curve of 0.801±0.040 (95% confidence interval 0.722 - 0.879; P<0.001). High preoperative NLR was also associated with long intensive care unit (ICU) LOS (P=0.035). Preoperative NLR predicted longer hospital LOS with a sensitivity of 63% and a specificity of 81.4%. Conclusion: Higher preoperative NLR was associated with long ICU and hospital LOS in patients undergoing TOF repair.


Assuntos
Humanos , Criança , Doenças Cardiovasculares/etiologia , Doenças Cardiovasculares/epidemiologia , Sistema Cardiovascular , COVID-19 , China/epidemiologia , SARS-CoV-2
17.
Rev. bras. cir. cardiovasc ; 36(5): 589-598, Sept.-Oct. 2021. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1351658

RESUMO

Abstract Introduction: The Technical Performance Score (TPS) was developed and subsequently refined at the Boston Children's Hospital. Our objective was to translate and validate its application in a developing country. Methods: The score was translated into the Portuguese language and approved by the TPS authors. Subsequently, we studied 1,030 surgeries from June 2018 to October 2020. TPS could not be assigned in 58 surgeries, and these were excluded. Surgical risk score was evaluated using Risk Adjustment in Congenital Heart Surgery (or RACHS-1). The impact of TPS on outcomes was studied using multivariable linear and logistic regression adjusting for important perioperative covariates. Results: Median age and weight were 2.2 (interquartile range [IQR] = 0.5-13) years and 10.8 (IQR = 5.6-40) kilograms, respectively. In-hospital mortality was 6.58% (n=64), and postoperative complications occurred in 19.7% (n=192) of the cases. TPS was categorized as 1 in 359 cases (37%), 2 in 464 (47.7%), and 3 in 149 (15.3%). Multivariable analysis identified TPS class 3 as a predictor of longer hospital stay (coefficient: 6.6; standard error: 2.2; P=0.003), higher number of complications (odds ratio [OR]: 1.84; 95% confidence interval [CI]: 1.1-3; P=0.01), and higher mortality (OR: 3.2; 95% CI: 1.4-7; P=0.004). Conclusion: TPS translated into the Portuguese language was validated and showed to be able to predict higher mortality, complication rate, and prolonged postoperative hospital stay in a high-volume Latin-American congenital heart surgery program. TPS is generalizable and can be used as an outcome assessment tool in resource diverse settings.


Assuntos
Humanos , Lactente , Pré-Escolar , Criança , Adolescente , Cardiopatias Congênitas , Procedimentos Cirúrgicos Cardíacos , Complicações Pós-Operatórias , Boston , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Mortalidade Hospitalar , Países em Desenvolvimento , Tempo de Internação
18.
Braz J Cardiovasc Surg ; 36(3): 289-294, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-34387970

RESUMO

INTRODUCTION: The coronavirus disease 2019 (COVID-19) has negatively impacted healthcare services worldwide. We hypothesized that the pandemic would affect our case mix and mortality. Our objective was to study this impact. METHODS: We retrospectively studied all patients who underwent congenital heart surgeries from March 21st to August 21st in 2019 and 2020 using the institutional electronic database. We compared demographic data, preoperative and postoperative length of stay (LOS), risk stratification using Risk Adjustment for Congenital Heart Surgery (RACHS) classification and outcomes in both periods. RESULTS: We observed a 66.7% decrease in our surgical volume (285 × 95 patients). Patients operated in the pre-pandemic period were older (911.3 [174.8 - 5953.8] days-old) compared to the pandemic period (275 days-old; P<0.05). When the case mix was compared between periods, the percentage of neonatal surgery was increased in the pandemic era (8% × 21.1%; P<0.05), and the number of RACHS 1-2 surgeries decreased significantly (60.7 × 27.4%; P<0.05). Preoperative LOS was increased in the pandemic period (1.2 × 7 days; P=0.001). There was no significant increment in mortality (P=0.1). Two patients tested positive for COVID-19 in the postoperative period and both died. CONCLUSION: Our program observed a sudden decrease in surgical volume and a consequent increase in surgical complexity. There was a non-significant increment in mortality.


Assuntos
COVID-19 , Pandemias , Brasil/epidemiologia , Criança , Humanos , Recém-Nascido , Estudos Retrospectivos , SARS-CoV-2
19.
Braz J Cardiovasc Surg ; 36(5): 607-613, 2021 10 17.
Artigo em Inglês | MEDLINE | ID: mdl-34236799

RESUMO

INTRODUCTION: Elevated neutrophil-lymphocyte ratio (NLR) has been associated with poorer outcomes in cyanotic patients undergoing single ventricle palliation. Little is known about this biomarker on patients with tetralogy of Fallot (TOF), the most common cyanotic congenital heart disease. Our objective is to study the impact of preoperative NLR on outcomes of TOF patients undergoing total repair. METHODS: This retrospective study included 116 consecutive patients between January 2014 and December 2018. Preoperative NLR was measured from the last complete blood count test before the surgery. Using the cutoff value of 0.80, according to the receiver-operating characteristic (ROC) curve, the sample was divided into two groups (NLR < 0.80 and ≥ 0.80). The primary endpoint was hospital length of stay (LOS). RESULTS: ROC curves showed that higher preoperative NLR was associated with longer hospital LOS, with an area under the curve of 0.801±0.040 (95% confidence interval 0.722 - 0.879; P<0.001). High preoperative NLR was also associated with long intensive care unit (ICU) LOS (P=0.035). Preoperative NLR predicted longer hospital LOS with a sensitivity of 63% and a specificity of 81.4%. CONCLUSION: Higher preoperative NLR was associated with long ICU and hospital LOS in patients undergoing TOF repair.


Assuntos
Neutrófilos , Tetralogia de Fallot , Humanos , Contagem de Linfócitos , Linfócitos , Prognóstico , Curva ROC , Estudos Retrospectivos , Tetralogia de Fallot/cirurgia
20.
Physiol Rep ; 9(11): e14862, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34057301

RESUMO

BACKGROUND: Lymphatic abnormalities play a role in effusions in individuals with a Fontan circulation. Recent results using near-infrared fluorescence imaging disclosed an increased contraction frequency of lymphatic vessels in Fontan patients compared to healthy controls. It is proposed that the elevated lymphatic pumping seen in the Fontan patients is necessary to maintain habitual interstitial fluid balance. Hyperthermia has previously been used as a tool for lymphatic stress test. By increasing fluid filtration in the capillary bed, the lymphatic workload and contraction frequency are increased accordingly. Using near-infrared fluorescence imaging, the lymphatic functional reserve capacity in Fontan patients were explored with a lymphatic stress test. METHODS: Fontan patients (n = 33) were compared to a group of 15 healthy individuals of equal age, weight, and gender. The function of the superficial lymphatic vessels in the lower leg during rest and after inducing hyperthermia was investigated, using near-infrared fluorescence imaging. RESULTS: Baseline values in the Fontan patients showed a 57% higher contraction frequency compared to the healthy controls (0.4 ± 0.3 min-1 vs. 0.3 ± 0.2 min-1 , p = 0.0445). After inducing stress on the lymphatic vessels with hyperthermia the ability to increase contraction frequency was decreased in the Fontan patients compared to the controls (0.6 ± 0.5 min-1 vs. 1.2 ± 0.8 min-1 , p = 0.0102). CONCLUSIONS: Fontan patients had a higher lymphatic contraction frequency during normal circumstances. In the Fontan patients, the hyperthermia response is dampened indicating that the functional lymphatic reserve capacity is depressed. This diminished reserve capacity could be part of the explanation as to why some Fontan patients develop late-onset lymphatic complications.


Assuntos
Técnica de Fontan/efeitos adversos , Doenças Linfáticas/etiologia , Adulto , Estudos de Casos e Controles , Feminino , Humanos , Doenças Linfáticas/patologia , Sistema Linfático/patologia , Vasos Linfáticos/patologia , Masculino , Espectroscopia de Luz Próxima ao Infravermelho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...